Read/Write to mapped IO
Categories:
OSByte call | Action | Available on: | |||
---|---|---|---|---|---|
(dec) | (hex) | BBC | Master | Electron | |
146 | 92 | Read IO in &FCxx FRED | x | x | x |
147 | 93 | Write IO in &FCxx FRED | x | x | x |
148 | 94 | Read IO in &FDxx JIM | x | x | x |
149 | 95 | Write IO in &FDxx JIM | x | x | x |
150 | 96 | Read IO in &FExx SHEILA | x | x | x |
151 | 97 | Write IO in &FExx SHEILA | x | x | x |
Entry parameters
X | Address within specified page for the call |
---|
On exit:
A | preserved |
---|---|
X | undefined |
C | undefined |
Refer to the hardware secion about the FRED, JIM & SHEILA 1MHz buses.